Fault Diagnosis of Ball Screw Pair in the Treatment of Common Faults of CNC Machine Tools

October 09, 2024

The majority of ball screw pair failures are caused by reduced motion quality, excessive backlash, mechanical creep, and poor lubrication. Wwill analyze the causes of different failure phenomena of ball screws and put forward corresponding solutions.

 

precision ball screw

1. High roughness value of processed parts

1) The lubricating oil of the guide rail is not enough, causing the sliding plate to crawl

Method: Add lubricating oil to eliminate lubrication failure

 2) The ball screw is partially rough or damaged

Method: Replace or repair the screw

 3) The screw bearing is damaged and the movement is not stable

Method: Replace damaged bearings

 4)The servo motor is not adjusted well, and the gain is too large

Method: Adjust the servo motor control system

 

2. Large reverse error and unstable processing accuracy

1) Loose cone sleeve of screw shaft coupling

Method: Retighten and repeat the test with a dial indicator

2) The screw shaft slide plate is too tight or too loose with the pressure plate

Method: Re-adjust or repair, use 0.03mm ruler to be qualified

3)Screw shaft slide with wedge iron is too tight or too loose

Method: Re-adjust or repair to make the contact rate reach over 70%

 

 

3. Too large  torque of the ball screws

1) Two skateboards cooperate with the pressure plate too tight or damaged

Method: Readjust or repair the pressure plate to make the 0.04mm caliper plug not qualified

2) The ball screw nut reverser is damaged, the ball screw is stuck or the shaft end nut pretension is too large

Method: Repair or replace the screw and adjust it carefully

3) Servo motor and ball screw are connected to different shafts

Method: Adjust the coaxial and tighten the connection seat

 

4. Poor lubrication of screw nut

1) Whether the oil separator divides the oil

Method: Check the quantitative oil separator

2) Whether the oil pipe is blocked

Method: Remove dirt and make the tubing unblocked

 

5. Ball screw noise

1) The ball screw bearing gland is not pressed properly

Method: Adjust the gland to make it tight against the bearing

2) Poor lubrication of ball screw

Method: Check the oil separator and the oil circuit to make sure the oil is sufficient

 

ball screw for CNC
Nous contacter

Author:

Mr. hojama

Phone/WhatsApp:

18068430089

Produits populaires
You may also like
Related Categories

Envoyer à ce fournisseur

Sujet:
E-mail :
message:

Your message must be betwwen 20-8000 characters

Nous contacter

Author:

Mr. hojama

Phone/WhatsApp:

18068430089

Produits populaires
We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

envoyer